Specification

Symbol

TPS10-30

 

Dimensions

TPS10-30

 

Working condition

In its steady state, the valve blocks flow at ①,
whileallowing flow to pass from ② to ③.
On attainment of apre-determined pressure at ①, 
the cartridge shifts toopen ① to ②.

 

Technical Data

Max working Pressure:207bar
Flow Max:See Performance Chart
Internal Leakage:82cc/min.max.to 85%of nominal setting
Filtration Of oil:25μm or better
Medium use temperature:-30~+110℃
Cavity:10-3
Installation Torque:32~35Nm

 

Performance

TPS10-30

 

Ordering code

TPS10-30

Products Inquiry