Specification

Symbol

FR2-10-4F

 

Dimensions

FR2-10-4F

 

Working condition

Nozzle ③ maintains a constant flow rate and is not affected by changes in load pressure at the preferred nozzle ③ or bypass nozzle ②.
When the load pressure of nozzle ③ reaches the set overflow pressure, the oil will overflow at Nozzle ④.
The overflow fluid can be connected to the fuel tank or bypassed.

 

Technical Data

Max working Pressure:207bar
Flow Setting:1-19 L/min
Maximum Entrance:38 L/min
Filtration Of Oil:20μm or better
Medium use temperature:-30~+110℃
Cavity:10-4
Installation Torque:34~37Nm

 

Performance

FR2-10-4F

 

Ordering code

FR2-10-4F

Products Inquiry