Specification

Symbol

FR-16-3F

 

Dimensions

FR-16-3F

 

Working condition

The valve maintainsaconstantflowrate from ③ regardless ofload pressure changesinthe systemdownstream of ③, or in the bypass leg at ②. The valve'sspool maintains a constant differential pressure of 6.5baracross afixed internal orifice, thereby regulatng thehydraulicflowrate from ① to ③. The valve is a priority type regulator, delivering the pumpflow to ③ first, then bypassing excess to ②. All ports maybe fully pressurized. Flow out of priority port ③ may varybased on input flow amount, particularly with lowertemperatures and increased fluid viscosities. Settings mayneed to be established through correlation study. Consultfactory.

 

Technical Data

Max working Pressure:241bar
Maximum adjustment flow:113lpm(30gpm)
Maximum input:190lpm(50.0gpm)
Standard Compenstor est Spring5.5bar(80psi)
FlowMaintenance Accuracy:76lpm(20gpm)±10%
 76~114lpm(20~30gpm)±15%
Filtration Of oil:20μm or better
Medium use temperature:-30~+110℃
Cavity:16-3
Installation Torque:62.6~73.4Nm

 

Performance

FR-16-3F

 

Ordering code

FR-16-3F

Products Inquiry