Working condition
The valve maintainsaconstantflowrate from ③ regardless ofload pressure changesinthe systemdownstream of ③, or in the bypass leg at ②. The valve'sspool maintains a constant differential pressure of 6.5baracross afixed internal orifice, thereby regulatng thehydraulicflowrate from ① to ③. The valve is a priority type regulator, delivering the pumpflow to ③ first, then bypassing excess to ②. All ports maybefully pressurized. Flow out of priority port ③ may varybased on input flow amount, particularly with lowertemperatures and increased fluid viscosities. Settings mayneed to be established through correlation study. Consultfactory.
Technical Data
| Max working Pressure: | 240bar |
| Maximum adjustment flow: | 49.2lpm(13.0gpm) |
| Maximum input: | 94.6lpm(25.0gpm) |
| Standard Compenstor est Spring | 6.5bar(95psi) |
| FlowMaintenance Accuracy: | 3.811.4lpm(1.0~3.0gpm)±15% |
| 11.4~45.4lpm(3.0~12.0gpm)±10% | |
| Filtration Of oil: | 20μm or better |
| Medium use temperature: | -30~+110℃ |
| Cavity: | 12-3 |
| Installation Torque: | 40.6Nm |