Specification

Symbol

FR-12-3F

 

Dimensions

FR-12-3F

 

Working condition

The valve maintainsaconstantflowrate from ③ regardless ofload pressure changesinthe systemdownstream of ③, or in the bypass leg at ②. The valve'sspool maintains a constant differential pressure of 6.5baracross afixed internal orifice, thereby regulatng thehydraulicflowrate from ① to ③. The valve is a priority type regulator, delivering the pumpflow to ③ first, then bypassing excess to ②. All ports maybefully pressurized. Flow out of priority port ③ may varybased on input flow amount, particularly with lowertemperatures and increased fluid viscosities. Settings mayneed to be established through correlation study. Consultfactory.

 

Technical Data

Max working Pressure:240bar
Maximum adjustment flow:49.2lpm(13.0gpm)
Maximum input:94.6lpm(25.0gpm)
Standard Compenstor est Spring6.5bar(95psi)
FlowMaintenance Accuracy:3.811.4lpm(1.0~3.0gpm)±15%
 11.4~45.4lpm(3.0~12.0gpm)±10%
Filtration Of oil:20μm or better
Medium use temperature:-30~+110℃
Cavity:12-3
Installation Torque:40.6Nm

 

Performance

FR-12-3F

 

Ordering code

FR-12-3F

Products Inquiry