Specification
Symbol

Dimensions

Working condition
The valve maintains a constant flow rate out of ② regardless of load pressure changesin the circuit downstream of ②. The fixed control orifice is factory preset to customerflow specification. The valve begins to respond to load changes when the flow through the valve createsa pressure diferential across the control orifice greater than 5.5 bar, with accurate flowmaintenance from 7.6 to 240 bar.
Reverse flow (② to ①)returns through the controlorifice and is non-compensated.
Technical Data
| Max working Pressure: | 250bar |
| Rated flow rate: | 0.41/min.min.,22.71/min.max |
| FlowMaintenance Accuracy: | 0.37 to 1.85L/min.setting+20% |
| 1.89 to 5.63L/min.setting+15% | |
| 5.68 to 22.7L/min.setting+10% | |
| Filtration Of Oil: | 20μm or better |
| Medium use temperature: | -30~+110℃ |
| Cavity: | 10-2 |
| Installation Torque: | 33.9~36.7Nm |
Performance

Ordering code

Products Inquiry
Related Products