Specification

Symbol

FR-10

 

Dimensions

FR-10

 

Working condition

The valve maintains a constant flow rate out of ② regardless of load pressure changesin the circuit downstream of ②. The fixed control orifice is factory preset to customerflow specification. The valve begins to respond to load changes when the flow through the valve createsa pressure diferential across the control orifice greater than 5.5 bar, with accurate flowmaintenance from 7.6 to 240 bar.
Reverse flow (② to ①)returns through the controlorifice and is non-compensated.

 

Technical Data

Max working Pressure:250bar
Rated flow rate:0.41/min.min.,22.71/min.max
FlowMaintenance Accuracy:0.37 to 1.85L/min.setting+20%
 1.89 to 5.63L/min.setting+15%
 5.68 to 22.7L/min.setting+10%
Filtration Of Oil:20μm or better
Medium use temperature:-30~+110℃
Cavity:10-2
Installation Torque:33.9~36.7Nm

 

Performance

FR-10

 

Ordering code

FR-10

Products Inquiry