Specification

Symbol

TCBBC

 

Dimensions

TCBBC

 

Working condition

Counterbalance valves with pilot assist are meant forcontrolon overrunning load.
The heck valve allows freeflow from port ② to port ① while a direct-acting, pilot-assisted relief valve controls flow from port ① to ② port. Pilot assist at port ③ lowers the effective setting of therelief valve at rate determined by the pilot ratio.

 

Features
Counterbalance valves should be set at least 1.3 times themaximum load induced pressure.
Fullclockwise setting is less than 14 bar.
Backpressure at port ② adds to the effective relief settingat a ratio of 1 plus the pilot ratio times the backpressure.
Reseat exceeds 85%of set pressure when the valve isstandard set. Setting lower than the standard set pressuremay result in lowerresead percentages.
Factory pressure setting established at 30cc/min(2in³/min) 

 

Technical Data

Max working Pressure:280bar
Flow Max:See Performance Chart
Recommended load pressure:215bar
Internal Leakage:5 drops/min
Pilot Ratio:3:1
Filtration Of Oil:25μm or better
Medium use temperature:-30~+110℃
Cavity:T-11A
Installation Torque:41~47Nm

 

Performance

TCBBC

 

Ordering code

TCBBC

Products Inquiry